Other Electrical Equipment Suppliers
Air conditioners capacitor
Broadly applied to starting and running of AC single-phase motors at 50Hz(60Hz) frequency for family air conditioners and high power illuminators for the sake of power factor compensation.
AC single-phase motor capacitor
Broadly applied to starting and running of AC single-phase motors at 50Hz(60Hz) frequency for family air conditioners and high power illuminators for the sake of power factor compensation.
Al/Zn Metallized film
1.1.1 Small capacitance loss over long service time. 1.1.2 Thick coated lay facilitates metallikon, compared with Al film. 1.1.3 In time metal spraying zinc oxide makes the low resistivity 1.1.4 High dielectric strength
AC Motor Capacitor CBB61
The capacitor takes heavy-edge metallized Al/Zn film as electrodes and dielectric. It is impregnated with flame-retardant epoxy resin and canned in cubic ABS or PBT plastic case with characteristics of small size, reliable performance and long endurance.
AC Motor Capacitor CBB60
The capacitor takes heavy-edge metallized Al/Zn PP film as electrodes and dielectric. Its components are sealed with flame-retardant epoxy resin. It has cylindrical outline with high moisture resistance and stability.
ACSR Conductor
National Switchgears is a manufacturer and supplier of wide gamut of Stay Wire and ACSR which suits every requirement of our clients owing to their strength and corrosion resistance capacity.
Tripler power generator
This type of generator is used for alternator induced over voltage withstand test of the pressure transformer, electric motor and the transformer in order to check up on the principal and subordinate insulating strength. It is also can be used for the 150Hz electrical source of short-time operations
Generator rotor impedance tester
type of generator rotor with ac impedance instrument is my company launched a new generation of enhanced with ac impedance tester, increased the display and print ac impedance characteristic curve and can realize data with the PC online download and editor of the test report function.
Transformers OLTC Tester
This type of tester is used to measure and analyze the electric property of the on-load tap-changer of power transformer. It can measure the parameters automatically.
Transformer load loss and no-load capacity of Test
Single machine can complete under 1000kVA distribution transformers and full-electric flow load test; About a third of the rated power flow can be completed under 2500kVA distribution transformers load test(About a third of the rated flow, electric instrument can be converted to the rated flow load loss electric parameters).
Intelligent Transformer empty load loss tester
This type of test set is used for monitoring the actual qualities of the off the line and the ongoing power transformers. It can be the spot test for the unloaded and loaded loss characteristic of the transformers. At the same time, it can meet the measurements of the related parameters including the electric current, voltage and power loss of the three phases or single-phase power transformer.
Intelligent electrical parameters measuring instru
The tester can measure the no-load of the transformer, and the active current (voltage) value, power factors of the short-circuit experiment at the same time with computer controlling, digital display, synchronous samples in avoid of many traditional shortages.
Automatic variable than the group Tester
This type of equipment can be used to test the transformation ratio, the polarity, the bracket and the inaccuracy of the single-phase or three phase transformers.
Electrical transformer of automatic comprehensive
This Comprehensive Test-bed is specialized in taking on the project system engineering construction of the power transformer standard testing house. It is responsible for the upgrade and reconstruction of the technical equipment as a general contractor from planning programming
Transformer winding characteristics of deformation
This type of instrument is adopted by introduction of foreign technology and the latest nondestructive examination equipment of the power transformer internal fault. It is used for confirming the degree of the deformation of transformer internal winding which is the important method of the preventative nondestructive examination
SERVICES